Short answer: a centred logo should clear no more than roughly 10% of the symbol's total area — about 31% of its width — and the code must be encoded at error correction level H. Below that it scans reliably; above it, a phone may read it from one angle and fail from another.
The percentages are not a rule of thumb imported from a design blog. They are the boundary we measured and then enforced in the generator, and the reason the boundary exists is worth understanding before you spend money on a print run.
Error correction is the budget you are spending
A QR code is not a solid picture: it is a grid of modules with Reed–Solomon error correction woven through the data. The correction level sets how much of the code can be damaged, missing or covered and still be reconstructed:
- L — about 7% recoverable
- M — about 15%
- Q — about 25%
- H — about 30%
A logo sits on top of the modules and destroys them. That is not damage a decoder can "look past" with cleverness; it is erased data, so the logo's footprint is paid for directly out of the recovery budget. At level L, a 10% logo would consume more than the code can spare. At level H it consumes about a third of it, which still leaves room for the smear of a phone camera held at an angle, a laminated surface, or a thumb over one corner.
This is why the QrMyWay generator forces level H whenever a logo is
embedded, whatever the correction selector says — and shows
EC H* next to the code so the override is visible rather than
silent.
The measurement behind the 31%
The constraint is per axis, in modules, not in pixels. We encoded payloads, cleared a square block behind the logo, and decoded the result with a standard optical reader at roughly the resolution a phone camera delivers (a 640-pixel sample of the rendered code). On a version-2 symbol — 25×25 modules, 625 in total — this is what happened at level H:
- An 8×8 cleared block (64 modules, 10.2% of the symbol) still decoded.
- A 9×9 cleared block (81 modules, 13%) did not.
Level H claims about 30% of codewords recoverable, which sounds like far more headroom than 13%. In practice the recoverable share is lower and it is unevenly distributed: cover a contiguous central square and you lose whole codewords plus alignment and timing structure around them. The generator therefore caps the clear box at 31.6% of the symbol's modules per axis — the 8×8 point, with a small margin — and shrinks the drawn logo to stay inside it.
Why the same logo fails on short content
Module count depends on how much data you encode. A phone number might fit in a 21×21 symbol; a long vCard with an address needs a much larger grid. A logo that occupies 22% of the image width covers far more modules on the 21×21 symbol than on the 45×45 one.
This is the most common way a design "works for one code but not another". If you size a logo on a long URL and then reuse the same style for a short text code, the second code is the one that fails. The cap exists so that does not happen quietly: shorter payloads automatically get a smaller drawn logo.
A practical recipe
- Enter the real content first. The symbol size follows the data, so a placeholder URL gives you the wrong module count.
- Keep the logo around 18–22% of the code's width. That is inside the safe band with room for print error.
- Leave the logo's background plate opaque and light, and the logo artwork dark. A transparent logo over dark modules is unreadable to a scanner even when it looks fine to you.
- Keep the quiet zone. Cropping the white border to make the code look tighter kills scans at the edges, where the finder patterns live.
- Test the exported file, not the preview on your monitor — scan it from the screen and from a printout at the size you will actually use.
One limit to know before you pass a design on: Share link copies an address that rebuilds the whole design in another browser, and a logo image too large to fit in that address is left out of the link — the button says so when it happens. Send the logo file separately, or hand over the exported PNG instead of a link.
What it looks like when it is borderline
Borderline codes fail intermittently, which is worse than failing outright: a phone may read a code at 20 cm but not at 40, or in daylight but not under a warm lamp. If your preview shows a verification warning, treat it as a prediction of that behaviour rather than an inconvenience — reduce the logo size or increase the payload's error correction headroom, then test again.
The generator applies both rules automatically: level H when a logo is present, and a module cap that shrinks oversized logos. The scannability guide covers the other things that break codes, and the about page explains how these figures were measured.